Hello Matt, While writing an ADM1032 driver for Linux, I came upon a few incorrectnesses and omissions in the data sheet (revision C). I thought you might be interested in a report, so that you can have the errors fixed in the next revisions. 1* Page 6, right column "When Flags 1 and 0 are set" should be "When flag 1 or 0 is set". Either flag can trigger the THERM output. 2* Page 7, left column Table VI would benefit a comment about why higher conversion rates need a lower average supply current. The reason is given at the bottom of the column, but that's not where you would be looking for it (IMHO). 3* Page 7, right column "This value written to this register" should be "The value written to this register". 4* Page 8 The die revision code is missing. Since I already told Mary about that, it might be already fixed. Thanks a lot for your great data sheets and excellent support. -- Jean Delvare http://www.ensicaen.ismra.fr/~delvare/