I'll take a look at at76c50x-usb in general and bringing over this patch specifically. Unfortunately, I still had one disconnect oops with the patch installed. Netconsole was not configured, so I did not catch it. There were several other successful disconnects without Oops though. It may need locking as none is currently present, but does a one way transition device_unplugged 0 -> 1 need a lock? Jason On Sat, Feb 7, 2009 at 6:29 AM, Kalle Valo <kalle.valo@xxxxxx> wrote: > On Thu, Feb 5, 2009 at 6:03 AM, Jason Andryuk <jandryuk@xxxxxxxxx> wrote: >> flush_workqueue needs to be called instead of the generic one and the >> associated functions need to be modified to prevent re-adding >> themselves to the workqueue. > > Good fix. Can you please port this to the at76c50x-usb driver I posted > this morning? > > Kalle > -- To unsubscribe from this list: send the line "unsubscribe linux-wireless" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html