On Monday 01 February 2016 13:30:37 Johannes Berg wrote: > On Mon, 2016-02-01 at 13:24 +0100, Sven Eckelmann wrote: > > The change from cur_tp to the function > > minstrel_get_tp_avg/minstrel_ht_get_tp_avg changed the unit used for > > the > > current throughtput. For example in minstrel_ht the correct > > conversion between them would be: > > > > mrs->cur_tp / 10 == minstrel_ht_get_tp_avg(..). > > > > This factor 10 must also be included in the calculation of > > minstrel_get_expected_throughput and > > minstrel_ht_get_expected_throughput to > > get similar results as before the change. > > > > 10 is a pretty expensive factor, perhaps that should use 16 instead? Not really funny but I will change the title. Kind regards, Sven
Attachment:
signature.asc
Description: This is a digitally signed message part.