[PATCH v1 1/1] watchdog: simatic: Use idiomatic selection of P2SB

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



While it's pretty much theoretical to be otherwise, make sure
that P2SB is selected only for X86. This is idiomatic dependency
which is used by all others who select it. Use it for Simatic
as well.

Signed-off-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx>
---
 drivers/watchdog/Kconfig | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
index a75f6acb986b..751458959411 100644
--- a/drivers/watchdog/Kconfig
+++ b/drivers/watchdog/Kconfig
@@ -1685,7 +1685,7 @@ config SIEMENS_SIMATIC_IPC_WDT
 	depends on SIEMENS_SIMATIC_IPC && PCI
 	default y
 	select WATCHDOG_CORE
-	select P2SB
+	select P2SB if X86
 	help
 	  This driver adds support for several watchdogs found in Industrial
 	  PCs from Siemens.
-- 
2.40.0.1.gaa8946217a0b