Re: debugging oops after disconnecting Nexio USB touchscreen

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Fri, 4 Dec 2009, Ondrej Zary wrote:

> > Furthermore, the patch shows that the second-to-last argument to
> > usb_fill_bulk_urb() -- the completion function -- is NULL.  That is
> > strictly illegal and it should have caused an oops as soon as the URB
> > was used.
> 
> Thanks for catching this. usbmon showed no ACK packets so it didn't work
> at all. The device did not care. It started to work after adding a
> complete function.

What started to work?  If you don't send any ACK packets, it doesn't 
make any difference whether the completion function is set or not.


> Seems that -EPIPE is returned only after the device is disconnected. Adding a 
> check for -EPIPE to usbtouch_irq() and not submitting the urb again seems to 
> fix the problem!

Fix which problem?  The unending resubmissions or the oops in ehci-hcd?

BTW, does the touchscreen run at high speed or at full speed?

Alan Stern

--
To unsubscribe from this list: send the line "unsubscribe linux-usb" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html