The Silicon Labs IFS-USB-DATACABLE is used in conjunction with for example the Quint UPSes. It is used to enable Modbus communication with the UPS to query configuration, power and battery status. Signed-off-by: Kees Jan Koster <kjkoster@xxxxxxxxxxxx> --- drivers/usb/serial/cp210x.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/usb/serial/cp210x.c b/drivers/usb/serial/cp210x.c index 832ad592b7ef..cdea1bff3b70 100644 --- a/drivers/usb/serial/cp210x.c +++ b/drivers/usb/serial/cp210x.c @@ -120,6 +120,7 @@ static const struct usb_device_id id_table[] = { { USB_DEVICE(0x10C4, 0x826B) }, /* Cygnal Integrated Products, Inc., Fasttrax GPS demonstration module */ { USB_DEVICE(0x10C4, 0x8281) }, /* Nanotec Plug & Drive */ { USB_DEVICE(0x10C4, 0x8293) }, /* Telegesis ETRX2USB */ + { USB_DEVICE(0x10C4, 0x82AA) }, /* Silicon Labs IFS-USB-DATACABLE used with Quint UPS */ { USB_DEVICE(0x10C4, 0x82EF) }, /* CESINEL FALCO 6105 AC Power Supply */ { USB_DEVICE(0x10C4, 0x82F1) }, /* CESINEL MEDCAL EFD Earth Fault Detector */ { USB_DEVICE(0x10C4, 0x82F2) }, /* CESINEL MEDCAL ST Network Analyzer */ -- 2.37.1 (Apple Git-137.1)