[PATCH v8 1/3] usb: dwc3: xilinx: fix uninitialized return value

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



A previous patch to skip part of the initialization when a USB3 PHY was
not present could result in the return value being uninitialized in that
case, causing spurious probe failures. Initialize ret to 0 to avoid this.

Fixes: 9678f3361afc ("usb: dwc3: xilinx: Skip resets and USB3 register settings for USB2.0 mode")
Signed-off-by: Robert Hancock <robert.hancock@xxxxxxxxxx>
---
 drivers/usb/dwc3/dwc3-xilinx.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/usb/dwc3/dwc3-xilinx.c b/drivers/usb/dwc3/dwc3-xilinx.c
index e14ac15e24c3..a6f3a9b38789 100644
--- a/drivers/usb/dwc3/dwc3-xilinx.c
+++ b/drivers/usb/dwc3/dwc3-xilinx.c
@@ -99,7 +99,7 @@ static int dwc3_xlnx_init_zynqmp(struct dwc3_xlnx *priv_data)
 	struct device		*dev = priv_data->dev;
 	struct reset_control	*crst, *hibrst, *apbrst;
 	struct phy		*usb3_phy;
-	int			ret;
+	int			ret = 0;
 	u32			reg;
 
 	usb3_phy = devm_phy_optional_get(dev, "usb3-phy");
-- 
2.31.1