On Sat, Aug 29, 2020 at 03:42:50PM +0200, Bjørn Mork wrote: > The USB composition, defining the set of exported functions, is dynamic > in newer Quectel modems. Default functions can be disabled and > alternative functions can be enabled instead. The alternatives > includes class functions using interface pairs, which should be > handled by the respective class drivers. > > Active interfaces are numbered consecutively, so static > blacklisting based on interface numbers will fail when the > composition changes. An example of such an error, where the > option driver has bound to the CDC ECM data interface, > preventing cdc_ether from handling this function: > > T: Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#= 2 Spd=480 MxCh= 0 > D: Ver= 2.00 Cls=ef(misc ) Sub=02 Prot=01 MxPS=64 #Cfgs= 1 > P: Vendor=2c7c ProdID=0125 Rev= 3.18 > S: Manufacturer=Quectel > S: Product=EC25-AF > C:* #Ifs= 6 Cfg#= 1 Atr=a0 MxPwr=500mA > A: FirstIf#= 4 IfCount= 2 Cls=02(comm.) Sub=06 Prot=00 > I:* If#= 0 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=option > E: Ad=81(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 1 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option > E: Ad=83(I) Atr=03(Int.) MxPS= 10 Ivl=32ms > E: Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=02(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 2 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option > E: Ad=85(I) Atr=03(Int.) MxPS= 10 Ivl=32ms > E: Ad=84(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=03(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 3 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option > E: Ad=87(I) Atr=03(Int.) MxPS= 10 Ivl=32ms > E: Ad=86(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=04(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 4 Alt= 0 #EPs= 1 Cls=02(comm.) Sub=06 Prot=00 Driver=(none) > E: Ad=89(I) Atr=03(Int.) MxPS= 16 Ivl=32ms > I:* If#= 5 Alt= 0 #EPs= 0 Cls=0a(data ) Sub=00 Prot=00 Driver=option > I: If#= 5 Alt= 1 #EPs= 2 Cls=0a(data ) Sub=00 Prot=00 Driver=option > E: Ad=88(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=05(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > > Another device with the same id gets correct drivers, since the > interface of the network function happens to be blacklisted by option: > > T: Bus=01 Lev=02 Prnt=02 Port=01 Cnt=01 Dev#= 3 Spd=480 MxCh= 0 > D: Ver= 2.00 Cls=ef(misc ) Sub=02 Prot=01 MxPS=64 #Cfgs= 1 > P: Vendor=2c7c ProdID=0125 Rev= 3.18 > S: Manufacturer=Android > S: Product=Android > C:* #Ifs= 5 Cfg#= 1 Atr=a0 MxPwr=500mA > I:* If#= 0 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=option > E: Ad=81(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 1 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option > E: Ad=83(I) Atr=03(Int.) MxPS= 10 Ivl=32ms > E: Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=02(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 2 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option > E: Ad=85(I) Atr=03(Int.) MxPS= 10 Ivl=32ms > E: Ad=84(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=03(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 3 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=00 Prot=00 Driver=option > E: Ad=87(I) Atr=03(Int.) MxPS= 10 Ivl=32ms > E: Ad=86(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=04(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > I:* If#= 4 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=qmi_wwan > E: Ad=89(I) Atr=03(Int.) MxPS= 8 Ivl=32ms > E: Ad=88(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms > E: Ad=05(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms > > Change rules for EC21, EC25, BG96 and EG95 to match vendor specific > serial functions only, to prevent binding to class functions. Require > 2 endpoints on ff/ff/ff functions, avoiding the 3 endpoint QMI/RMNET > network functions. > > Cc: AceLan Kao <acelan.kao@xxxxxxxxxxxxx> > Cc: Sebastian Sjoholm <ssjoholm@xxxxxxx> > Cc: Dan Williams <dcbw@xxxxxxxxxx> > Cc: stable@xxxxxxxxxxxxxxx > Signed-off-by: Bjørn Mork <bjorn@xxxxxxx> Thanks, Bjørn. Now applied. Johan