Re: [PATCH 10/19] usbnet: smsc95xx: Replace smsc95xx_mdio_read() with phy_read()

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



> I wonder, if I use the phylib functions instead of the ad-hoc ones in
> the MAC driver, is there still a problem with synchronization ?

You would need to look deep into phylib. When does it reset the PHY?
Configure auto-neg, setup interrupts, etc? It looks like both are
going to do this, so i expect they are going to mess each other up.

      Andrew