On 07/03/2014 12:55 AM, Stephen Warren wrote:
On 07/02/2014 06:19 AM, Alexandre Courbot wrote:
DSI support has been fixed to support continuous clock behavior that the
panel used on SHIELD requires, so finally add its device tree node since
it is functional.
diff --git a/arch/arm/boot/dts/tegra114-roth.dts b/arch/arm/boot/dts/tegra114-roth.dts
+ host1x@50000000 {
+ dsi@54300000 {
That node looks fine, but I wonder why we need to mark a bunch of
regulators as always-on? shouldn't the references to vdd-supply and
power-supply from this node be enough? If not, perhaps the tree
structure of the regulators isn't correct, or the DSI or panel bindings
don't allow enough regulators to be referenced?
regulator-always-on is indeed not needed for vdd_lcd. I actually had a
patch in my tree removing this line that I forgot to squash. Will post a
v2 for this patch that fixes this, thanks.
vdd-2v8-display needs to remain always-on however. Here we may hit a
limitation of the simple-panel driver, where only one power supply can
be provided.
--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html