Re: [PATCH 0/3] Tegra USB probe order issue fix

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, 2 Jul 2014, Tuomas Tynkkynen wrote:

> Hi all,
> 
> This series fixes a probe order issue with the Tegra EHCI driver.
> Basically, the register area of the 1st USB controller contains some
> registers that are global to all of the controllers, but that are also
> cleared when reset is asserted to the 1st controller. So if (say) the
> 3rd controller would be the first one to finish probing successfully,
> then the reset that happens during the 1st controller's probe would
> result in broken USB. So the before doing anything with the USB HW,
> we should reset the 1st controller once, and then never ever reset
> it again.

This sounds very much like the sort of thing that ought to be described 
in DT.  It is a hardware dependence, and DT exists for the purpose of 
describing the hardware.

Alan Stern

--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [ARM Kernel]     [Linux ARM]     [Linux ARM MSM]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]

  Powered by Linux