Re: [PATCH v4 2/3] regulator: tps6586x: add and use correct voltage table

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 12/03/2013 03:18 PM, Stefan Agner wrote:
> Depending on the regulator version, the voltage table might be 
> different. Use version specific regulator tables in order to
> select correct voltage table. For the following regulator versions
> different voltage tables are now used:
> 
> * TPS658623: Use correct voltage table for SM2 * TPS658643: New
> voltage table for SM2
> 
> Both versions are in use on the Colibri T20 module. Make use of
> the correct tables by requesting the correct SM2 voltage of 1.8V.
> 
> This change is not backward compatible since an old driver is not
> able to correctly set that value. The value 1.8V is out of range
> for the old driver and will refuse to probe the device. The
> regulator starts with default settings and the driver shows
> appropriate error messages.
> 
> On Colibri T20, the old value used to work with TPS658623 since
> the driver applied a wrong voltage table too. However, the
> TPS658643 used on V1.2 devices uses yet another voltage table and
> those broke that pseudo-compatibility. The regulator driver now has
> the correct voltage table for both regulator versions and those the
> correct voltage can be used in the device tree.

Acked-by: Stephen Warren <swarren@xxxxxxxxxx>
(yes, taking this through the MFD tree with patch 1/3 makes sense)
--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [ARM Kernel]     [Linux ARM]     [Linux ARM MSM]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]

  Powered by Linux