On Fri, Nov 09, 2012 at 10:36:13AM -0700, Stephen Warren wrote: > On 11/09/2012 06:22 AM, Thierry Reding wrote: > > On Fri, Nov 09, 2012 at 01:56:55PM +0100, Thierry Reding wrote: > >> The Harmony board has an Analog Devices ADT7461 temperature > >> sensor connected to the DVC bus. It can be used to monitor the > >> ambient (local) and on-die (remote) temperatures. > > > > Note that I haven't actually tested this, as I no longer have > > access to Harmony hardware. Testing can easily be done either by > > reading the files from sysfs directly or by running the sensors > > utility from the lm-sensors package. > > OK, I can test this. The same comment about the DT node name that I > made for the other patch applies here too. Alright, I'll rename the node. Thierry