On Wed, Jun 22, 2016 at 03:42:07PM +0200, Geert Uytterhoeven wrote: > Add an SPI slave handler responding with the time of reception of the > last SPI message. > > This can be used by an external microcontroller as a dead man's switch. The subject says boot up time, this says time of reception of the last message. Which is it? > +static int spi_slave_time_send(struct spi_device *spi) > +{ > + __be32 msg[2]; > + u32 rem_ns; > + u64 ts; > + > + ts = local_clock(); > + rem_ns = do_div(ts, 1000000000) / 1000; > + > + msg[0] = cpu_to_be32(ts); > + msg[1] = cpu_to_be32(rem_ns); > + > + return spi_write(spi, &msg, sizeof(msg)); > +} Looks like uptime which is a third thing. > +static int spi_slave_time_remove(struct spi_device *spi) > +{ > + struct spi_slave_time_priv *priv = spi_get_drvdata(spi); > + > + /* FIXME Doesn't work, as spi_write() is blocked on a completion */ > + kthread_stop(priv->thread); spi_async()? Still no cancellation on the actual operation but it pushes it more inside the framework.