Hi Philipp, On Wed, 2017-07-19 at 17:07 +0200, Philipp Zabel wrote: > On Tue, 2017-07-18 at 20:25 +0300, Eugeniy Paltsev wrote: > > The HSDK v1 periphery IPs can be reset by accessing some registers > > from the CGU block. > > > > The list of available reset lines is documented in the DT bindings. > > > > [snip] > > --- a/drivers/reset/Kconfig > > +++ b/drivers/reset/Kconfig > > @@ -34,6 +34,12 @@ config RESET_BERLIN > > ? help > > ? ??This enables the reset controller driver for Marvell > > Berlin SoCs. > > ? > > +config RESET_HSDK_V1 > > + bool "HSDK v1 Reset Driver" > > + default n > > I suppose there will be a SOC_HSDK_V1 or similar in the future so > that > we can hide this option and enable it by default like the other reset > drivers? Actually we don't have (and don't planning to add) such SOC/board- specific kconfig option, so I am wondering if it is OK to just left this option not hidden? > > [snip] > > + > > +#define CGU_ARC_RST_CTRL 0x0 > > +#define CGU_SYS_RST_CTRL 0x20 > > +#define CGU_DDR_RST_CTRL 0x40 > > +#define CGU_TUN_RST_CTRL 0x60 > > The ARC, DDR, and TUN reset control registers are never used. Ok, I'll remove unused register defines. > > [snip] > > regards > Philipp > Thanks. -- ?Eugeniy Paltsev