On 10/9/24 15:17, Ulf Hansson wrote: > On Tue, 8 Oct 2024 at 11:34, Thomas Richard <thomas.richard@xxxxxxxxxxx> wrote: >> >> With this flag, if a device is marked on the wakeup path, the corresponding >> PM domain is kept powered on. > > Perhaps extend this with some more information that it fixes a problem > for the uart console too? Yes, I'll send a v2 (only the patch 1/2) with a more verbose commit message. > >> >> Suggested-by: Théo Lebrun <theo.lebrun@xxxxxxxxxxx> >> Signed-off-by: Thomas Richard <thomas.richard@xxxxxxxxxxx> > > Should we add a stable/fixes tag? I guess no. The first implementation, which was reverted, didn't have a stable/fixes tag. Regards, Thomas