On Fri, Nov 24, 2023 at 09:58:19AM -0300, Fabio Estevam wrote: > Hi Paul, > > On Fri, Nov 24, 2023 at 9:55 AM Paul Geurts <paul_geurts@xxxxxxx> wrote: > > > > When using the serial port as RS485 port, the tx statemachine is used to > > control the RTS pin to drive the RS485 transceiver TX_EN pin. When the > > TTY port is closed in the middle of a transmission (for instance during > > userland application crash), imx_uart_shutdown disables the interface > > and disables the Transmission Complete interrupt. afer that, > > imx_uart_stop_tx bails on an incomplete transmission, to be retriggered > > by the TC interrupt. This interrupt is disabled and therefore the tx > > statemachine never transitions out of SEND. The statemachine is in > > deadlock now, and the TX_EN remains low, making the interface useless. > > > > imx_uart_stop_tx now checks for incomplete transmission AND whether TC > > interrupts are enabled before bailing to be retriggered. This makes sure > > the state machine handling is reached, and is properly set to > > WAIT_AFTER_SEND. > > > > Fixes: cb1a60923609 serial: imx: implement rts delaying for rs485 > > One nit: the correct format for the Fixes tag is: > > Fixes: cb1a60923609 ("serial: imx: implement rts delaying for rs485") > > And no blank line is needed between the Fixes and Signed-off-by line. It's not really a "nit", our tools will complain if this is in the wrong format as so many things depend on this being correct. Paul, can you make a v3 with this change? And really, this should have been v3 anyway, as the difference being you added a changelog from v2 :) thanks, greg k-h