Re: kernel 5.19.8: "Oxford Semiconductor Ltd OXPCIe952 Dual Native 950 UART" gets wrong baudrate (PCI ID 1415:c158)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



I get incorrect baudrates, my oscilloscope gives:

Programmed	Measured

  2400		  5208
  4800		 13150
  9600		 10410
 19200		 71420
 38400		142000
 57600		201600
115200		138800


On 2022-09-13 10:21, Greg Kroah-Hartman wrote:
On Mon, Sep 12, 2022 at 09:59:08PM +0200, Anders Blomdell wrote:
Reverting commits
   366f6c955d4d1a5125ffcd6875ead26a3c7a2a1c
   9c5c8aaed50bf3478073ab51b8b1f3f5327d3cfa
fixes my problems.

What problems exactly?

And why not cc: the developers of those commits?

thanks,

greg k-h

--
Anders Blomdell                  Email: anders.blomdell@xxxxxxxxxxxxxx
Department of Automatic Control
Lund University                  Phone:    +46 46 222 4625
P.O. Box 118
SE-221 00 Lund, Sweden



[Index of Archives]     [Kernel Newbies]     [Security]     [Netfilter]     [Bugtraq]     [Linux PPP]     [Linux FS]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Linmodem]     [Device Mapper]     [Linux Kernel for ARM]