I get incorrect baudrates, my oscilloscope gives:
Programmed Measured
2400 5208
4800 13150
9600 10410
19200 71420
38400 142000
57600 201600
115200 138800
On 2022-09-13 10:21, Greg Kroah-Hartman wrote:
On Mon, Sep 12, 2022 at 09:59:08PM +0200, Anders Blomdell wrote:
Reverting commits
366f6c955d4d1a5125ffcd6875ead26a3c7a2a1c
9c5c8aaed50bf3478073ab51b8b1f3f5327d3cfa
fixes my problems.
What problems exactly?
And why not cc: the developers of those commits?
thanks,
greg k-h
--
Anders Blomdell Email: anders.blomdell@xxxxxxxxxxxxxx
Department of Automatic Control
Lund University Phone: +46 46 222 4625
P.O. Box 118
SE-221 00 Lund, Sweden