On Fri, Dec 27, 2013 at 10:43:23AM +0400, Alexander Shiyan wrote: > Hello. > > On Fri, Dec 27, 2013 at 12:00:20PM +0530, Tushar Behera wrote: > > > On 27 December 2013 10:48, Greg KH <gregkh@xxxxxxxxxxxxxxxxxxx> wrote: > > > > On Fri, Dec 27, 2013 at 10:37:28AM +0530, Tushar Behera wrote: > > > >> The hard-coded values clash with the values set for amba-pl011 serial > > > >> driver. Because of this there is no serial output on Samsung boards > > > >> if amba-pl011 is enabled alongwith samsung-serial driver. > > > >> > > > >> Remove the hardcoded values and let the framework decide on > > > >> appropriate major/minor number. This is required for multi-platform > > > >> development work on Exynos platform. > > > >> > > > >> Signed-off-by: Tushar Behera <tushar.behera@xxxxxxxxxx> > ... > > > >> #define S3C24XX_SERIAL_NAME "ttySAC" > > > >> -#define S3C24XX_SERIAL_MAJOR 204 > > > >> -#define S3C24XX_SERIAL_MINOR 64 > > > >> > > > >> /* macros to change one thing to another */ > > > >> > > > >> @@ -951,8 +949,6 @@ static struct uart_driver s3c24xx_uart_drv = { > > > >> .nr = CONFIG_SERIAL_SAMSUNG_UARTS, > > > >> .cons = S3C24XX_SERIAL_CONSOLE, > > > >> .dev_name = S3C24XX_SERIAL_NAME, > > > >> - .major = S3C24XX_SERIAL_MAJOR, > > > >> - .minor = S3C24XX_SERIAL_MINOR, > > > > > > > > Doesn't this break existing systems and configurations that are > > > > expecting 204:64 as the location of this serial port? > > > > > > > > > > I tested this on Exynos4210-Origen, Exynos5250-Arndale board, it works > > > fine there. I haven't tested on any older boards. > > > > How did it work? You are relying on some userspace tools to do this > > properly, right? What about systems without those specific tools? > > Can this issue be resolved by using MODULE_ALIAS_CHARDEV() > in the driver code? How exactly would that work? -- To unsubscribe from this list: send the line "unsubscribe linux-serial" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html