Re: [PATCHv2] pm80xx: fix Adaptec 71605H hang

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 07/26/2013 06:43 PM, Hans Verkuil wrote:
> The IO command size is 128 bytes for these new controllers as opposed to 64
> for the old 8001 controller.
> 
> The Adaptec out-of-tree driver did this correctly. After comparing the two
> this turned out to be the crucial difference.
> 
> So don't hardcode the IO command size, instead use pm8001_ha->iomb_size as
> that is the correct value for both old and new controllers.
> 
> Signed-off-by: Hans Verkuil <hans.verkuil@xxxxxxxxx>
> Cc: stable@xxxxxxxxxxxxxxx      # for v3.10 and up
snip

Thanks Hans.
Looks good now.

Acked-by: Jack Wang <xjtuwjp@xxxxxxxxx>

James,

Could you consider to include this fix into your fixes tree, without
this fix new Adaptec controller support is broken, sorry for that.


Jack
--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]