Re: lp8000 and 2.6.18-rc6

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



It's not an LP8000 issue...  It's a Clariion issue...
The inquiry data for the 4 target ports looks only partially formed
(no PID, odd SCSI rev). The guess is that the clariion isn't set up
to export any real luns to you yet. See if there's lun-masking
(or selective presentation) that you have to enable on the clariion
based on the wwpn of the adapter.

-- james s

Alberto Cammozzo wrote:
Hello,

I have a problem with the Emulex LP8000 lpfc driver:
- the kernel module loads fine and reports 4 luns from the storage
  (Clariion 4700),  also listed in /proc/scsi/scsi,  but
- there is no way to have a SCSI device attached (sdb, sdc, ...), even
  runing rescan-scsi-bus. The disks are not listed with fdisk -l.

It's the first time I use this setup... Am I missing something?

  Thank you for any help.

    Alberto



==== Uname -a:
Linux novantatre 2.6.18-rc6 #1 SMP Sat Sep 9 09:46:54 CEST 2006 i686 GNU/Linux

==== lsmod:
Module                  Size  Used by
lpfc 145600 0 scsi_transport_fc 25568 1 lpfc iscsi_tcp 19808 1 libiscsi 17504 1 iscsi_tcp
scsi_transport_iscsi    23244  3 iscsi_tcp,libiscsi
skge 31312 0 [...]

==== From dmesg:
Emulex LightPulse Fibre Channel SCSI driver 8.1.9
Copyright(c) 2004-2006 Emulex.  All rights reserved.
PCI: Enabling device 0000:04:01.0 (0158 -> 015b)
ACPI: PCI Interrupt 0000:04:01.0[A] -> GSI 52 (level, low) -> IRQ 23
scsi6 :  on PCI bus 04 device 08 irq 23
lpfc 0000:04:01.0: 0:1303 Link Up Event x1 received Data: x1 x1 x0 x0
  Vendor: DGC       Model:                   Rev: 0850
  Type:   Direct-Access                      ANSI SCSI revision: 04
  Vendor: DGC       Model:                   Rev: 0850
  Type:   Direct-Access                      ANSI SCSI revision: 04
  Vendor: DGC       Model:                   Rev: 0850
  Type:   Direct-Access                      ANSI SCSI revision: 04
  Vendor: DGC       Model:                   Rev: 0850
  Type:   Direct-Access                      ANSI SCSI revision: 04

===== from /proc/scsi/scsi:
Host: scsi6 Channel: 00 Id: 00 Lun: 00
  Vendor: DGC      Model:                  Rev: 0850
  Type:   Direct-Access                    ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 01 Lun: 00
  Vendor: DGC      Model:                  Rev: 0850
  Type:   Direct-Access                    ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 02 Lun: 00
  Vendor: DGC      Model:                  Rev: 0850
  Type:   Direct-Access                    ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 03 Lun: 00
  Vendor: DGC      Model:                  Rev: 0850
  Type:   Direct-Access                    ANSI SCSI revision: 04


-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]
  Powered by Linux