Hi Tudor,

On Thu, 14 Dec 2023 at 10:52, Tudor Ambarus <tudor.ambarus@xxxxxxxxxx> wrote:
>
> The gs101 clock names are derived from the clock register names under
> some certain rules. In particular, for the gate clocks the following is
> documented and expected in the gs101 clock driver:
>
>   Replace CLK_CON_GAT_CLKCMU      with CLK_GOUT_CMU and gout_cmu
>   Replace CLK_CON_GAT_GATE_CLKCMU with CLK_GOUT_CMU and gout_cmu
>
>   For gates remove _UID _BLK _IPCLKPORT and _RSTNSYNC
>
> The CMU TOP gate clock names missed to include the required "CMU"
> differentiator which will cause name collisions with the gate clock names
> of other clock units. Fix the TOP gate clock names and include "CMU" in
> their name.
>
> Fixes: 0a910f160638 ("dt-bindings: clock: Add Google gs101 clock management unit bindings")
> Signed-off-by: Tudor Ambarus <tudor.ambarus@xxxxxxxxxx>

[...]

Thanks for spotting this inconsistency on the cmu_top gates and fixing it!

Reviewed-by: Peter Griffin <peter.griffin@xxxxxxxxxx>