In MFCv12, some section of firmware gets updated at each MFC run. Hence we need to reload original firmware for each run at the start. Cc: linux-fsd@xxxxxxxxx Signed-off-by: Smitha T Murthy <smithatmurthy@xxxxxxxxx> Signed-off-by: Aakarsh Jain <aakarsh.jain@xxxxxxxxxxx> --- drivers/media/platform/samsung/s5p-mfc/s5p_mfc_ctrl.c | 10 ++++++++-- 1 file changed, 8 insertions(+), 2 deletions(-) diff --git a/drivers/media/platform/samsung/s5p-mfc/s5p_mfc_ctrl.c b/drivers/media/platform/samsung/s5p-mfc/s5p_mfc_ctrl.c index b49159142c53..503487f34a80 100644 --- a/drivers/media/platform/samsung/s5p-mfc/s5p_mfc_ctrl.c +++ b/drivers/media/platform/samsung/s5p-mfc/s5p_mfc_ctrl.c @@ -51,8 +51,14 @@ int s5p_mfc_load_firmware(struct s5p_mfc_dev *dev) * into kernel. */ mfc_debug_enter(); - if (dev->fw_get_done) - return 0; + /* In case of MFC v12, RET_SYS_INIT response from hardware fails due to + * incorrect firmware transfer and therefore it is not able to initialize + * the hardware. This causes failed response for SYS_INIT command when + * MFC runs for second time. So, load the MFC v12 firmware for each run. + */ + if (!IS_MFCV12(dev)) + if (dev->fw_get_done) + return 0; for (i = MFC_FW_MAX_VERSIONS - 1; i >= 0; i--) { if (!dev->variant->fw_name[i]) -- 2.17.1