[PATCH v2 2/6] iommu/exynos: Fix retval on getting clocks in probe

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



checkpatch reports next warning for clock getting code in probe
function:

    WARNING: ENOSYS means 'invalid syscall nr' and nothing else

Replace it with -ENOINT to make checkpatch happy.

Signed-off-by: Sam Protsenko <semen.protsenko@xxxxxxxxxx>
---
Changes in v2:
  - (none)

 drivers/iommu/exynos-iommu.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/iommu/exynos-iommu.c b/drivers/iommu/exynos-iommu.c
index 45fd4850bacb..0d150b383d04 100644
--- a/drivers/iommu/exynos-iommu.c
+++ b/drivers/iommu/exynos-iommu.c
@@ -689,7 +689,7 @@ static int exynos_sysmmu_probe(struct platform_device *pdev)
 
 	if (!data->clk && (!data->aclk || !data->pclk)) {
 		dev_err(dev, "Failed to get device clock(s)!\n");
-		return -ENOSYS;
+		return -ENOENT;
 	}
 
 	data->clk_master = devm_clk_get(dev, "master");
-- 
2.35.1