The Exynos7-specific code bits in ADC driver do not play with PHY: the field exynos_adc_data.needs_adc_phy is not set in exynos7_adc_data instance. Therefore the initialization code does not have to check if it is true. Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx> --- Only build tested. --- drivers/iio/adc/exynos_adc.c | 3 --- 1 file changed, 3 deletions(-) diff --git a/drivers/iio/adc/exynos_adc.c b/drivers/iio/adc/exynos_adc.c index 22131a677445..219c8eb32d16 100644 --- a/drivers/iio/adc/exynos_adc.c +++ b/drivers/iio/adc/exynos_adc.c @@ -449,9 +449,6 @@ static void exynos_adc_exynos7_init_hw(struct exynos_adc *info) { u32 con1, con2; - if (info->data->needs_adc_phy) - regmap_write(info->pmu_map, info->data->phy_offset, 1); - con1 = ADC_V2_CON1_SOFT_RESET; writel(con1, ADC_V2_CON1(info->regs)); -- 2.17.1