Hi Greg, On 2019-08-28 22:41, Greg Kroah-Hartman wrote: > On Mon, Aug 26, 2019 at 10:55:33AM +0200, Marek Szyprowski wrote: >> Hi Greg >> >> On 2019-08-08 11:41, Marek Szyprowski wrote: >>> Some PHYs (for example Exynos5 USB3.0 DRD PHY) require calibration to be >>> done after every USB HCD reset. Generic PHY framework has been already >>> extended with phy_calibrate() function in commit 36914111e682 ("drivers: >>> phy: add calibrate method"). This patch adds support for it to generic >>> PHY handling code in USB HCD core. >>> >>> Signed-off-by: Marek Szyprowski <m.szyprowski@xxxxxxxxxxx> >>> Tested-by: Anand Moon <linux.amoon@xxxxxxxxx> >>> Tested-by: Jochen Sprickerhof <jochen@xxxxxxxxxxxxxx> >> Greg: any chance to give it this a try in -next? If not, maybe You can >> point someone whose review will help? > Ah crap, this is me, not the PHY maintainer :( > > Can you resend this and I will be glad to review it. But it would also > be good to get Felipe's review as well. No problem, I will resend it again in a few minutes. Felipe already acked it: https://lkml.org/lkml/2019/8/8/460 Best regards -- Marek Szyprowski, PhD Samsung R&D Institute Poland