Hi Marek, On Wed, 20 Feb 2019 at 16:49, Marek Szyprowski <m.szyprowski@xxxxxxxxxxx> wrote: > > The maximum voltage value for BUCK8 regulator on Odroid XU3/4 boards is > set too low. Increase it to the 2000mV as specified on the board schematic. > So far the board worked fine, because of the bug in the PMIC driver, which > used incorrect step value for that regulator. It interpreted the voltage > value set by the bootloader as 1500mV and kept it unchanged. The regulator > driver has been however fixed recently in the commit 56b5d4ea778c > ("regulator: s2mps11: Fix steps for buck7, buck8 and LDO35"), what results > in reading the proper BUCK8 value and forcing it to 1500mV on boot. This > is not enough for proper board operation and results in eMMC errors during > heavy IO traffic. Increasing maximum voltage value for BUCK8 restores > original driver behavior and fixes eMMC issues. > Their is a pincrtl setting to configure Read Strobe (RDQS) added to support higher data rate RDSQ --------XMMC0RDQS/GPC0_7/EXT_INT9_7 will setting this bit help resolve the eMMC error Also we could increase the following samsung,read-strobe-delay = <150>; To increase stability of the eMMC. Best Regards -Anand