LDO35 uses 25 mV step, not 50 mV. Bucks 7 and 8 use 12.5 mV step instead of 6.25 mV. Wrong step caused over-voltage (LDO35) or under-voltage (buck7 and 8) if regulators were used (e.g. on Exynos5420 Arndale Octa board). Cc: <stable@xxxxxxxxxxxxxxx> Fixes: cb74685ecb39 ("regulator: s2mps11: Add samsung s2mps11 regulator driver") Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx> --- drivers/regulator/s2mps11.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/drivers/regulator/s2mps11.c b/drivers/regulator/s2mps11.c index ee4a23ab0663..134c62db36c5 100644 --- a/drivers/regulator/s2mps11.c +++ b/drivers/regulator/s2mps11.c @@ -362,7 +362,7 @@ static const struct regulator_desc s2mps11_regulators[] = { regulator_desc_s2mps11_ldo(32, STEP_50_MV), regulator_desc_s2mps11_ldo(33, STEP_50_MV), regulator_desc_s2mps11_ldo(34, STEP_50_MV), - regulator_desc_s2mps11_ldo(35, STEP_50_MV), + regulator_desc_s2mps11_ldo(35, STEP_25_MV), regulator_desc_s2mps11_ldo(36, STEP_50_MV), regulator_desc_s2mps11_ldo(37, STEP_50_MV), regulator_desc_s2mps11_ldo(38, STEP_50_MV), @@ -372,8 +372,8 @@ static const struct regulator_desc s2mps11_regulators[] = { regulator_desc_s2mps11_buck1_4(4), regulator_desc_s2mps11_buck5, regulator_desc_s2mps11_buck67810(6, MIN_600_MV, STEP_6_25_MV), - regulator_desc_s2mps11_buck67810(7, MIN_600_MV, STEP_6_25_MV), - regulator_desc_s2mps11_buck67810(8, MIN_600_MV, STEP_6_25_MV), + regulator_desc_s2mps11_buck67810(7, MIN_600_MV, STEP_12_5_MV), + regulator_desc_s2mps11_buck67810(8, MIN_600_MV, STEP_12_5_MV), regulator_desc_s2mps11_buck9, regulator_desc_s2mps11_buck67810(10, MIN_750_MV, STEP_12_5_MV), }; -- 2.17.1