On 18.02.2016 04:53, Anand Moon wrote: > Hi Krzysztof, > > On 17 February 2016 at 12:25, Krzysztof Kozlowski > <k.kozlowski@xxxxxxxxxxx> wrote: >> After adding cpufreq-dt support to Exynos542x, the Odroid XU3-Lite can >> be easily overheated when launching eight CPU-intensive tasks: >> thermal thermal_zone3: critical temperature reached(121 C),shutting down >> >> This seems to be specific to Odroid XU3-Lite board which officially >> supports lower frequencies than regular XU3 or XU4. When working at >> maximum CPU speed (1800 MHz big and 1300 MHz LITTLE) in warmer place for >> longer time, the fan fails to cool down the board and it reaches >> critical temperature. >> >> Add CPU cooling to Exynos5422/5800 to fix this issue. When reaching 95 >> degrees of Celsius, the board will slow down by 3 steps (around >> 1400/1000 MHz). When reaching 110 degrees of Celsius go to 600 MHz. >> >> Signed-off-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx> >> --- >> arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi | 41 +++++++++++++++++++++++++++ >> 1 file changed, 41 insertions(+) >> >> diff --git a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi b/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi >> index 2b289d7c0d13..66073ce29aee 100644 >> --- a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi >> +++ b/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi >> @@ -34,6 +34,16 @@ >> hysteresis = <5000>; /* millicelsius */ >> type = "active"; >> }; >> + cpu_alert3: cpu-alert-3 { >> + temperature = <95000>; /* millicelsius */ >> + hysteresis = <5000>; /* millicelsius */ >> + type = "passive"; >> + }; >> + cpu_alert4: cpu-alert-4 { >> + temperature = <110000>; /* millicelsius */ >> + hysteresis = <5000>; /* millicelsius */ >> + type = "passive"; >> + }; >> cpu_crit0: cpu-crit-0 { >> temperature = <120000>; /* millicelsius */ >> hysteresis = <0>; /* millicelsius */ >> @@ -53,6 +63,37 @@ >> trip = <&cpu_alert2>; >> cooling-device = <&fan0 2 3>; >> }; >> + >> + /* >> + * When reaching cpu_alert3, reduce CPU >> + * by 3 steps. On Exynos5422/5800 that would >> + * be: 1400 MHz and 1000 MHz. >> + */ >> + map3 { >> + trip = <&cpu_alert3>; >> + cooling-device = <&cpu0 3 3>; >> + }; >> + map4 { >> + trip = <&cpu_alert3>; >> + cooling-device = <&cpu4 3 3>; >> + }; >> + >> + /* >> + * When reaching cpu_alert4, reduce CPU >> + * to 600 MHz (11 steps for big, 7 steps for >> + * LITTLE). >> + * Exynos5420 has less OPPs and reversed >> + * numbering of CPUs (big/LITTLE) so this >> + * would not match. >> + */ >> + map5 { >> + trip = <&cpu_alert4>; >> + cooling-device = <&cpu0 7 7>; >> + }; >> + map6 { >> + trip = <&cpu_alert4>; >> + cooling-device = <&cpu4 11 11>; >> + }; >> }; >> }; >> }; >> -- >> 2.5.0 >> > > could you append this patch with following changes. Could you describe why? > diff --git a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi > b/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi > index 66073ce..4e72637 100644 > --- a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi > +++ b/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi > @@ -16,8 +16,8 @@ > thermal-zones { > cpu0_thermal: cpu0-thermal { > thermal-sensors = <&tmu_cpu0 0>; > - polling-delay-passive = <0>; > - polling-delay = <0>; > + polling-delay-passive = <250>; /* milliseconds */ > + polling-delay = <500>; /* milliseconds */ > trips { > cpu_alert0: cpu-alert-0 { > temperature = <50000>; /* > millicelsius */ > --- > On running linaro pm-qa diagnostic tool > ---------------------------------------------------------- > > thermal_01.28: checking 'thermal_zone2'/'trip_point_2_temp' ='110000'... Ok > thermal_01.29: checking 'cdev0_trip_point' exists in > '/sys/devices/virtual/thermal/thermal_zone0'... Ok > thermal_01.30: checking 'thermal_zone0/cdev0_trip_point' valid binding... Ok > thermal_01.31: checking 'cdev4_trip_point' exists in > '/sys/devices/virtual/thermal/thermal_zone0'... Ok > thermal_01.32: checking 'thermal_zone0/cdev4_trip_point' valid binding... Err > thermal_01.33: checking 'cdev4_trip_point' exists in > '/sys/devices/virtual/thermal/thermal_zone0'... Ok > thermal_01.34: checking 'thermal_zone0/cdev4_trip_point' valid binding... Err > thermal_01.35: checking 'cdev4_trip_point' exists in > '/sys/devices/virtual/thermal/thermal_zone0'... Ok > thermal_01.36: checking 'thermal_zone0/cdev4_trip_point' valid binding... Err > thermal_01.37: checking 'cdev4_trip_point' exists in > '/sys/devices/virtual/thermal/thermal_zone0'... Ok > thermal_01.38: checking 'thermal_zone0/cdev4_trip_point' valid binding... Err > > thermal_01: fail > ------------------------------------------------------- > I also got lot's of error. > > root@odroidxu4l:~# cpu[ 3050.847663] cpu cpu4: Failed to find dev_opp: -19 > [ 3171.640836] cpu cpu4: device_opp_debug_create_link: Failed to create link > [ 3171.646197] cpu cpu4: _add_list_dev: Failed to register opp debugfs (-12) > [ 3171.653574] cpu cpu7: device_opp_debug_create_link: Failed to create link > [ 3171.659752] cpu cpu7: _add_list_dev: Failed to register opp debugfs (-12) > [ 3171.697011] cpu cpu5: cpufreq_init: failed to get clk: -2 > [ 3171.732505] cpu cpu6: cpufreq_init: failed to get clk: -2 > [ 3171.768160] cpu cpu7: cpufreq_init: failed to get clk: -2 > > Tested on Odroid-XU4 > > Reviewed-by: Anand Moon <linux.amoon@xxxxxxxxx> > Tested-by: Anand Moon <linux.amoon@xxxxxxxxx> The patch is not sufficient. It does not work the way it should... BTW, I found the issue. The order of trip points in DT: thermal_zone0/trip_point_0_hyst:5000 thermal_zone0/trip_point_0_temp:50000 thermal_zone0/trip_point_0_type:active thermal_zone0/trip_point_1_hyst:5000 thermal_zone0/trip_point_1_temp:60000 thermal_zone0/trip_point_1_type:active thermal_zone0/trip_point_2_hyst:5000 thermal_zone0/trip_point_2_temp:70000 thermal_zone0/trip_point_2_type:active thermal_zone0/trip_point_3_hyst:0 thermal_zone0/trip_point_3_temp:120000 <---- this should be last one! thermal_zone0/trip_point_3_type:critical thermal_zone0/trip_point_4_hyst:5000 thermal_zone0/trip_point_4_temp:90000 thermal_zone0/trip_point_4_type:passive thermal_zone0/trip_point_5_hyst:5000 thermal_zone0/trip_point_5_temp:110000 thermal_zone0/trip_point_5_type:passive After fixing the order in DT, the cpu cooler starts working. Best regards, Krzysztof -- To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html