Javier, On Wed, Oct 8, 2014 at 1:46 AM, Javier Martinez Canillas <javier.martinez at collabora.co.uk> wrote: > Yes, you will need Chanwoo's series in order to use this. If also the > driver needs to set a default initial regulator operating mode, it will > need the series I'll post today but in that case also a .set_mode handler > is needed. In rk808 the mode isn't as complicated as the Maxim PMICs. There's only a "on in sleep" vs "off in sleep", not different sleep modes. Also the "on" vs "off" isn't mixed up with the sleep mode setting. ...so I think that the "mode" stuff isn't needed for rk808. -Doug