On Wed, May 29, 2024 at 11:12:13AM +0200, Geert Uytterhoeven wrote: > The main CAN clock is either the internal CANFD clock, or the external > CAN clock. Hence replace the two-valued enum by a simple boolean flag. > Consolidate all CANFD clock handling inside a single branch. > > Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> Nice simplification! Reviewed-by: Wolfram Sang <wsa+renesas@xxxxxxxxxxxxxxxxxxxx>