On Tue, Jul 17, 2018 at 04:52:15PM +0200, Niklas Söderlund wrote: > When tuning each tap is issued CMD19 twice and the result of both runs > recorded in host->taps. If the result is different between the two runs > the wrong sampling clock position was selected. Fix this by merging the > two runs and only keep the result for each tap if it was good in both > sets. > > Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@xxxxxxxxxxxx> So, I tested this patch without having patch 2 applied and it worked: Tested-by: Wolfram Sang <wsa+renesas@xxxxxxxxxxxxxxxxxxxx> Reviewed-by: Wolfram Sang <wsa+renesas@xxxxxxxxxxxxxxxxxxxx> Ulf, I think patches 1 & 3 are good and should be applied to 4.18 with stable attached. And I wonder if it was easier if I'd send you pull requests now that we are working with even more developers on SDHI? Simon, Niklas, what do you think?