On Wed, May 16, 2018 at 09:40:10AM +0200, Geert Uytterhoeven wrote: > Hi Simon, > > On Tue, May 15, 2018 at 10:00 AM, Simon Horman > <horms+renesas@xxxxxxxxxxxx> wrote: > > Describe CEU1 peripheral for Renesas R-Mobile A1 R8A7740 Soc. > > > > Signed-off-by: Simon Horman <horms+renesas@xxxxxxxxxxxx> > > --- > > v2 > > * Correct register range start address > > Thanks for your patch! > > Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> > > Minor question below. > > > --- a/arch/arm/boot/dts/r8a7740.dtsi > > +++ b/arch/arm/boot/dts/r8a7740.dtsi > > @@ -77,6 +77,16 @@ > > status = "disabled"; > > }; > > > > + ceu1: ceu@fe914000 { > > + reg = <0xfe914000 0x3000>; > > + compatible = "renesas,r8a7740-ceu"; > > + interrupts = <GIC_SPI 159 IRQ_TYPE_LEVEL_HIGH>; > > + clocks = <&mstp1_clks R8A7740_CLK_CEU21>; > > + clock-names = "ceu21"; > > Why the "clock-names" property? It's not mentioned in the DT bindings, and > may cause issues if the bindings are ever amended. Thanks, I copied this from CEU0 where you have also raised the same issue. I have dropped the property for now.