Hi Simon, On Tue, May 15, 2018 at 10:00 AM, Simon Horman <horms+renesas@xxxxxxxxxxxx> wrote: > Describe CEU1 peripheral for Renesas R-Mobile A1 R8A7740 Soc. > > Signed-off-by: Simon Horman <horms+renesas@xxxxxxxxxxxx> > --- > v2 > * Correct register range start address Thanks for your patch! Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> Minor question below. > --- a/arch/arm/boot/dts/r8a7740.dtsi > +++ b/arch/arm/boot/dts/r8a7740.dtsi > @@ -77,6 +77,16 @@ > status = "disabled"; > }; > > + ceu1: ceu@fe914000 { > + reg = <0xfe914000 0x3000>; > + compatible = "renesas,r8a7740-ceu"; > + interrupts = <GIC_SPI 159 IRQ_TYPE_LEVEL_HIGH>; > + clocks = <&mstp1_clks R8A7740_CLK_CEU21>; > + clock-names = "ceu21"; Why the "clock-names" property? It's not mentioned in the DT bindings, and may cause issues if the bindings are ever amended. > + power-domains = <&pd_a4r>; > + status = "disabled"; > + }; > + Gr{oetje,eeting}s, Geert -- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@xxxxxxxxxxxxxx In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds