Re: [PATCH 1/4] thermal: Add new thermal trend type to support quick cooling

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Amit/Rui,

> -----Original Message-----
> From: Amit Kachhap [mailto:amit.kachhap@xxxxxxxxxx]
> Sent: Friday, November 09, 2012 11:52 AM
> To: Zhang, Rui
> Cc: linux-pm@xxxxxxxxxxxxxxxxxxxxxxxxxx; linux-samsung-
> soc@xxxxxxxxxxxxxxx; linux-kernel@xxxxxxxxxxxxxxx; R, Durgadoss;
> lenb@xxxxxxxxxx; linux-acpi@xxxxxxxxxxxxxxx; jonghwa3.lee@xxxxxxxxxxx
> Subject: Re: [PATCH 1/4] thermal: Add new thermal trend type to support
> quick cooling
> 
> On 9 November 2012 09:21, Zhang Rui <rui.zhang@xxxxxxxxx> wrote:
> > On Thu, 2012-11-08 at 11:56 +0530, Amit Kachhap wrote:
> >> On 8 November 2012 11:31, Zhang Rui <rui.zhang@xxxxxxxxx> wrote:
> >> > On Thu, 2012-11-08 at 09:56 +0530, Amit Daniel Kachhap wrote:
> >> >> This modification adds 2 new thermal trend type
> THERMAL_TREND_RAISE_FULL
> >> >> and THERMAL_TREND_DROP_FULL. This thermal trend can be used to
> quickly
> >> >> jump to the upper or lower cooling level instead of incremental
> increase
> >> >> or decrease.
> >> >
> >> > IMO, what we need is a new more aggressive cooling governor which
> always
> >> > uses upper limit when the temperature is raising and lower limit when
> >> > the temperature is dropping.
> >> Yes I agree that a new aggressive governor is the best approach but
> >> then i thought adding a new trend type is a simple solution to achieve
> >> this and since most of the governor logic might be same as the
> >> step-wise governor. I have no objection in doing it through governor.
> >> >
> > hmmm,
> > I think a more proper way is to set the cooling state to upper limit
> > when it overheats and reduce the cooling state step by step when the
> > temperature drops.
> 
> No actually I was thinking of having a  simple governor with a feature
> like it only sets to upper level and lower level. Also since the
> temperature sensor is capable of interrupting for both increase in
> threshold(say 100C)  and fall in threshold (say 90C), so polling or
> step increments is not needed at all.
> Currently stepwise governor governor does that so we might change the
> macro name as,
> THERMAL_TREND_RAISE_STEP,
> THERMAL_TREND_DROP_STEP,
> THERMAL_TREND_RAISE_MAX,
> THERMAL_TREND_DROP_MAX,
> 
> and file step_wise.c can be named as state_wise.c or trend_wise.c.

Yes, in this particular case, we neither need to poll nor do step wise
operations. But, most of the other sensors need at least one of them.

So, I think we can try it this way:
	if (sensor supports interrupt) {
		'always' use RAISE_MAX and DROP_MAX;
	} else {
		Do Step wise operations
	}

And this could be plugged into step wise. I don't think we need a
complete new governor just to get this case working.

For this to work, we need a way for the governor to know 'whether the
sensor can work on interrupt mode'. May be introducing a new field in
tzd structure can help us here.

I am fine with any name for the governor :-)

Thanks,
Durga



[Index of Archives]     [Linux ACPI]     [Netdev]     [Ethernet Bridging]     [Linux Wireless]     [CPU Freq]     [Kernel Newbies]     [Fedora Kernel]     [Security]     [Linux for Hams]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux RAID]     [Linux Admin]     [Samba]