On Thu, 2018-06-28 at 08:07 -0500, Bjorn Helgaas wrote: > On Wed, Jun 27, 2018 at 05:21:35PM +0800, honghui.zhang@xxxxxxxxxxxx wrote: > > From: Honghui Zhang <honghui.zhang@xxxxxxxxxxxx> > > > > Mediatek's host controller have two slots, each have it's own control > > registers. The host driver need to identify which slot was connected > > in order to access the device's configuration space. There's problem > > for current host driver to find out which slot was connected to for > > a given EP device. > > The Mediatek host controller has two slots, each with its own control > registers. Thanks, I will update it in the next version. > > > Assuming each slot have connect with one EP device as below: > > > > host bridge > > bus 0 --> __________|_______ > > | | > > | | > > slot 0 slot 1 > > bus 1 -->| bus 2 --> | > > | | > > EP 0 EP 1 > > > > While PCI emulation, system software will scan all the PCI device > > s/While PCI emulation/During PCI enumeration/ Thanks, will update this. > > > starting from devfn 0. So it will get the proper port for slot0 and > > slot1 device when using PCI_SLOT(devfn) for match. But it will get > > the wrong slot for EP1: The devfn will be start from 0 when scanning > > EP1 behind slot1, it will get port0 since the PCI_SLOT(EP1) is match > > for port0's slot value. So the host driver should not using EP's devfn > > but the slot's devfn(the slot which EP was connected to) for match. > > > > This patch fix the mtk_pcie_find_port's logical by using the slot's > > devfn for match. > > > > Signed-off-by: Honghui Zhang <honghui.zhang@xxxxxxxxxxxx> > > Reviewed-by: Ryder Lee <ryder.lee@xxxxxxxxxxxx> > > --- > > drivers/pci/controller/pcie-mediatek.c | 17 +++++++++++++++-- > > 1 file changed, 15 insertions(+), 2 deletions(-) > > > > diff --git a/drivers/pci/controller/pcie-mediatek.c b/drivers/pci/controller/pcie-mediatek.c > > index 0baabe3..9cf7ecf 100644 > > --- a/drivers/pci/controller/pcie-mediatek.c > > +++ b/drivers/pci/controller/pcie-mediatek.c > > @@ -337,10 +337,23 @@ static struct mtk_pcie_port *mtk_pcie_find_port(struct pci_bus *bus, > > { > > struct mtk_pcie *pcie = bus->sysdata; > > struct mtk_pcie_port *port; > > + struct pci_dev *dev; > > + struct pci_bus *pbus; > > > > - list_for_each_entry(port, &pcie->ports, list) > > - if (port->slot == PCI_SLOT(devfn)) > > + list_for_each_entry(port, &pcie->ports, list) { > > mvebu has the identical hardware structure but uses an array instead > of a list: > > num = of_get_available_child_count(np); > pcie->ports = devm_kcalloc(dev, num, sizeof(*pcie->ports), GFP_KERNEL); > for_each_available_child_of_node(np, child) { > struct mvebu_pcie_port *port = &pcie->ports[i]; > mvebu_pcie_parse_port(pcie, port, child); > } > > It would be nice if mvebu and mtk used the same strategy so the code > looks the same. Seems there's different approach existing in current host controller driver for this, tegra PCIe is using list too. I guess I can change it to using array after this problem is fixed if you have strong opinion here. > > > + if (bus->number == 0 && port->slot == PCI_SLOT(devfn)) { > > Is the root bus number fixed at 0 or is it programmable? Many drivers > do something like this: The primary bus number is fixed at 0.(technically speaking, hardware will capture the very first value of primary bus number, once it's been captured, change the value in configuration space will not take effort. But the hardware default value is 0, the hardware will not response to other values except 0 at the first time. And the only way to touch the value in it's configuration space is using primary bus number 0. So it could be taken as fixed at 0.) > > if (bus->number == pcie->root_bus_nr) > > to handle the case of the root bus number being programmable. > > > return port; > > + } else if (bus->number != 0) { > > + pbus = bus; > > + do { > > + dev = pbus->self; > > + if (port->slot == PCI_SLOT(dev->devfn)) > > + return port; > > + > > + pbus = dev->bus; > > + } while (dev->bus->number != 0); > > You should not need to search up the tree of dev->bus->self. > > mvebu_pcie_find_port() checks the root port secondary and subordinate > bus numbers, which should work here, too. > I checked mvebu's host driver, it using software bridge to abstract a pseudo bridge. And access to this pseudo bridge's configuration space is all software behavior. If I following mvebu's way, I need to touch the hardware to read back the secondary and subordinary bus number, I think current software solution is more efficient. Or I could add per port parameter to store the bus_number, and update the value as mvebu's driver is doing. Do you think it's better than current solution? > > + } > > + } > > > > return NULL; > > } > > -- > > 2.6.4 > > > > > > _______________________________________________ > > linux-arm-kernel mailing list > > linux-arm-kernel@xxxxxxxxxxxxxxxxxxx > > http://lists.infradead.org/mailman/listinfo/linux-arm-kernel