On Sat, 31 Dec 2022 08:40:41 +0100, Sergio Paracuellos wrote: > Some devices like ZBT WE1326 and ZBT WF3526-P and some Netgear models need > to sleep a bit after call to mt7621_pcie_init_port() driver function to get > into reliable boots for both warm and hard resets. The needed time for these > devices to always detect the ports seems to be from 75 to 100 milliseconds. > There is no datasheet or something similar to really understand why this > extra time is needed in these devices but not in most of the boards which > use mt7621 SoC. This issue has been reported by openWRT community and the > complete discussion is in [0]. The selected time of 100 milliseconds has > been also tested in these devices ending up in an always working platform. > Hence, properly add the extra 100 milliseconds msleep() function call to make > also these devices work. > > [...] Applied to pci/controller/mt7621, thanks! [1/1] PCI: mt7621: Sleep a bit after power on the PCIs phy ports https://git.kernel.org/pci/pci/c/0cb2a8f3456f Thanks, Lorenzo