On Mon, Jul 16, 2012 at 06:31:10PM +0800, Axel Lin wrote: > According to the datasheet, the voltage for twl6030ldo_ops is not linear for > all cases. Linear mapping is only for the selection code from > 00000001 to 00011000. Applied, thanks.