From: Jarkko Nikula <jhnikula@xxxxxxxxx> I believe the VMMC2 constraints must be the same than with VAUX3. Older boards are using TWL4030 VMMC2 supply for internal MMC whereas newer are using VAUX3 that has more limited constraints defined in this same file. More over, the VMMC2 supply is used also for analog audio domain and the miminum analog voltage of the TLV320AIC34 codec is 2.7 V. To combine these two facts, the patch changes supply name to V28_A as the newer boards register VMMC2_30 for VAUX3 and uses the same constraints than VAUX3 since those constraints are ok for the TLV320AIC34. Signed-off-by: Jarkko Nikula <jhnikula@xxxxxxxxx> Cc: Adrian Hunter <adrian.hunter@xxxxxxxxx> Cc: Eduardo Valentin <eduardo.valentin@xxxxxxxxx> Signed-off-by: Tony Lindgren <tony@xxxxxxxxxxx> --- arch/arm/mach-omap2/board-rx51-peripherals.c | 6 +++--- 1 files changed, 3 insertions(+), 3 deletions(-) diff --git a/arch/arm/mach-omap2/board-rx51-peripherals.c b/arch/arm/mach-omap2/board-rx51-peripherals.c index 4377a4c..b803f47 100644 --- a/arch/arm/mach-omap2/board-rx51-peripherals.c +++ b/arch/arm/mach-omap2/board-rx51-peripherals.c @@ -370,9 +370,9 @@ static struct regulator_init_data rx51_vmmc1 = { static struct regulator_init_data rx51_vmmc2 = { .constraints = { - .name = "VMMC2_30", - .min_uV = 1850000, - .max_uV = 3150000, + .name = "V28_A", + .min_uV = 2800000, + .max_uV = 3000000, .apply_uV = true, .valid_modes_mask = REGULATOR_MODE_NORMAL | REGULATOR_MODE_STANDBY, -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html