We currently are getting the following warning after a system suspend: Powerdomain (vpe_pwrdm) didn't enter target state 0 Looks like this is because the STANDBYMODE bit for SMART_IDLE should not be used. The TRM "Table 12-348. VPE_SYSCONFIG" says that the value for SMART_IDLE is "0x2: Same behavior as bit-field value of 0x1". But if the SMART_IDLE value is used, PM_VPE_PWRSTST LASTPOWERSTATEENTERED bits always show value of 3. Let's fix the issue by dropping SMART_IDLE for vpe. And let's also add the missing the powerdomain for vpe. Fixes: 1a2095160594 ("ARM: dts: dra7: Add ti-sysc node for VPE") Cc: Benoit Parrot <bparrot@xxxxxx> Reported-by: Kevin Hilman <khilman@xxxxxxxxxxxx> Signed-off-by: Tony Lindgren <tony@xxxxxxxxxxx> --- arch/arm/boot/dts/dra7-l4.dtsi | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/arch/arm/boot/dts/dra7-l4.dtsi b/arch/arm/boot/dts/dra7-l4.dtsi --- a/arch/arm/boot/dts/dra7-l4.dtsi +++ b/arch/arm/boot/dts/dra7-l4.dtsi @@ -4189,11 +4189,11 @@ target-module@1d0010 { /* 0x489d0000, ap 27 30.0 */ reg = <0x1d0010 0x4>; reg-names = "sysc"; ti,sysc-midle = <SYSC_IDLE_FORCE>, - <SYSC_IDLE_NO>, - <SYSC_IDLE_SMART>; + <SYSC_IDLE_NO>; ti,sysc-sidle = <SYSC_IDLE_FORCE>, <SYSC_IDLE_NO>, <SYSC_IDLE_SMART>; + power-domains = <&prm_vpe>; clocks = <&vpe_clkctrl DRA7_VPE_VPE_CLKCTRL 0>; clock-names = "fck"; #address-cells = <1>; -- 2.35.1