We are currently using a wrong ADC range for the battery detection. The ADC returns the battery temperature if connected. Cc: Merlijn Wajer <merlijn@xxxxxxxxxx> Cc: Pavel Machek <pavel@xxxxxx> Acked-by: Pavel Machek <pavel@xxxxxx> Signed-off-by: Tony Lindgren <tony@xxxxxxxxxxx> --- drivers/power/supply/cpcap-charger.c | 7 ++++--- 1 file changed, 4 insertions(+), 3 deletions(-) diff --git a/drivers/power/supply/cpcap-charger.c b/drivers/power/supply/cpcap-charger.c --- a/drivers/power/supply/cpcap-charger.c +++ b/drivers/power/supply/cpcap-charger.c @@ -176,20 +176,21 @@ static enum power_supply_property cpcap_charger_props[] = { POWER_SUPPLY_PROP_CURRENT_NOW, }; +/* No battery always shows temperature of -40000 */ static bool cpcap_charger_battery_found(struct cpcap_charger_ddata *ddata) { struct iio_channel *channel; - int error, value; + int error, temperature; channel = ddata->channels[CPCAP_CHARGER_IIO_BATTDET]; - error = iio_read_channel_raw(channel, &value); + error = iio_read_channel_processed(channel, &temperature); if (error < 0) { dev_warn(ddata->dev, "%s failed: %i\n", __func__, error); return false; } - return value == 1; + return temperature > -20000 && temperature < 60000; } static int cpcap_charger_get_charge_voltage(struct cpcap_charger_ddata *ddata) -- 2.23.0