The IPU and DSP remote processor cores and their corresponding MMUs on DRA7 SoCs have hardreset lines associated with them and are controlled by a PRCM reset line each. Any clkctrl enable/disable operations cannot be checked for module enabled/disabled status independent of the reset operation, and this causes some unwanted timeouts in the kernel and unbalanced states for these clocks. These details should be handled by the driver integration code itself. Add the CLKF_NO_IDLEST flag to both the IPU and DSP clkctrl clocks so that these module status checks are skipped. Signed-off-by: Tero Kristo <t-kristo@xxxxxx> --- drivers/clk/ti/clk-7xx.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/drivers/clk/ti/clk-7xx.c b/drivers/clk/ti/clk-7xx.c index b57fe09b428b..94e69cdc2bd2 100644 --- a/drivers/clk/ti/clk-7xx.c +++ b/drivers/clk/ti/clk-7xx.c @@ -25,7 +25,7 @@ static const struct omap_clkctrl_reg_data dra7_mpu_clkctrl_regs[] __initconst = }; static const struct omap_clkctrl_reg_data dra7_dsp1_clkctrl_regs[] __initconst = { - { DRA7_DSP1_MMU0_DSP1_CLKCTRL, NULL, CLKF_HW_SUP, "dpll_dsp_m2_ck" }, + { DRA7_DSP1_MMU0_DSP1_CLKCTRL, NULL, CLKF_HW_SUP | CLKF_NO_IDLEST, "dpll_dsp_m2_ck" }, { 0 }, }; @@ -41,7 +41,7 @@ static const struct omap_clkctrl_bit_data dra7_mmu_ipu1_bit_data[] __initconst = }; static const struct omap_clkctrl_reg_data dra7_ipu1_clkctrl_regs[] __initconst = { - { DRA7_IPU1_MMU_IPU1_CLKCTRL, dra7_mmu_ipu1_bit_data, CLKF_HW_SUP, "ipu1-clkctrl:0000:24" }, + { DRA7_IPU1_MMU_IPU1_CLKCTRL, dra7_mmu_ipu1_bit_data, CLKF_HW_SUP | CLKF_NO_IDLEST, "ipu1-clkctrl:0000:24" }, { 0 }, }; @@ -137,7 +137,7 @@ static const struct omap_clkctrl_reg_data dra7_ipu_clkctrl_regs[] __initconst = }; static const struct omap_clkctrl_reg_data dra7_dsp2_clkctrl_regs[] __initconst = { - { DRA7_DSP2_MMU0_DSP2_CLKCTRL, NULL, CLKF_HW_SUP, "dpll_dsp_m2_ck" }, + { DRA7_DSP2_MMU0_DSP2_CLKCTRL, NULL, CLKF_HW_SUP | CLKF_NO_IDLEST, "dpll_dsp_m2_ck" }, { 0 }, }; @@ -164,7 +164,7 @@ static const struct omap_clkctrl_reg_data dra7_l3main1_clkctrl_regs[] __initcons }; static const struct omap_clkctrl_reg_data dra7_ipu2_clkctrl_regs[] __initconst = { - { DRA7_IPU2_MMU_IPU2_CLKCTRL, NULL, CLKF_HW_SUP, "dpll_core_h22x2_ck" }, + { DRA7_IPU2_MMU_IPU2_CLKCTRL, NULL, CLKF_HW_SUP | CLKF_NO_IDLEST, "dpll_core_h22x2_ck" }, { 0 }, }; -- 2.17.1 -- Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki