[PATCH 07/10] mmc: card: Use R1 responses for stop cmds for read requests

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



While using open ended transmission and thus ending the transfer by
sending a stop command, we shall use R1B only for writes and R1 shall
be used for reads. Previously R1B were used in both cases.

Signed-off-by: Ulf Hansson <ulf.hansson@xxxxxxxxxx>
---
 drivers/mmc/card/block.c |    7 ++++++-
 1 file changed, 6 insertions(+), 1 deletion(-)

diff --git a/drivers/mmc/card/block.c b/drivers/mmc/card/block.c
index 7b5424f..87cd2b0 100644
--- a/drivers/mmc/card/block.c
+++ b/drivers/mmc/card/block.c
@@ -1335,7 +1335,6 @@ static void mmc_blk_rw_rq_prep(struct mmc_queue_req *mqrq,
 	brq->data.blksz = 512;
 	brq->stop.opcode = MMC_STOP_TRANSMISSION;
 	brq->stop.arg = 0;
-	brq->stop.flags = MMC_RSP_SPI_R1B | MMC_RSP_R1B | MMC_CMD_AC;
 	brq->data.blocks = blk_rq_sectors(req);
 
 	/*
@@ -1378,9 +1377,15 @@ static void mmc_blk_rw_rq_prep(struct mmc_queue_req *mqrq,
 	if (rq_data_dir(req) == READ) {
 		brq->cmd.opcode = readcmd;
 		brq->data.flags |= MMC_DATA_READ;
+		if (brq->mrq.stop)
+			brq->stop.flags = MMC_RSP_SPI_R1 | MMC_RSP_R1 |
+					MMC_CMD_AC;
 	} else {
 		brq->cmd.opcode = writecmd;
 		brq->data.flags |= MMC_DATA_WRITE;
+		if (brq->mrq.stop)
+			brq->stop.flags = MMC_RSP_SPI_R1B | MMC_RSP_R1B |
+					MMC_CMD_AC;
 	}
 
 	if (do_rel_wr)
-- 
1.7.9.5

--
To unsubscribe from this list: send the line "unsubscribe linux-mmc" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html