Recently, A new clock and reset controller driver has been introduced to the ralink mips target[1]. It provides proper system control and adds more SoC specific compatible strings. In order to better initialize CPUs, this patch removes the outdated "ralink,mt7620a-sysc" and add all dt-binding documented compatible strings to the system controller match table. [1] https://lore.kernel.org/all/20230619040941.1340372-1-sergio.paracuellos@xxxxxxxxx/ Signed-off-by: Shiji Yang <yangshiji66@xxxxxxxxxxx> --- arch/mips/ralink/of.c | 7 ++++++- 1 file changed, 6 insertions(+), 1 deletion(-) diff --git a/arch/mips/ralink/of.c b/arch/mips/ralink/of.c index 53a2ae9ee..1c6c953d5 100644 --- a/arch/mips/ralink/of.c +++ b/arch/mips/ralink/of.c @@ -40,10 +40,15 @@ static const struct of_device_id mtmips_memc_match[] = { static const struct of_device_id mtmips_sysc_match[] = { { .compatible = "mediatek,mt7621-sysc" }, - { .compatible = "ralink,mt7620a-sysc" }, + { .compatible = "ralink,mt7620-sysc" }, + { .compatible = "ralink,mt7628-sysc" }, + { .compatible = "ralink,mt7688-sysc" }, { .compatible = "ralink,rt2880-sysc" }, { .compatible = "ralink,rt3050-sysc" }, + { .compatible = "ralink,rt3052-sysc" }, + { .compatible = "ralink,rt3352-sysc" }, { .compatible = "ralink,rt3883-sysc" }, + { .compatible = "ralink,rt5350-sysc" }, {} }; -- 2.30.2