Hi Laurent > > >> - s2d2 (for 200MHz) > > >> - s2d1 (for 400MHz) > > > > > > Thank you for the information. Do you mean that different FCP instances > > > use different clocks ? If so, could you tell us which clock is used by > > > each instance in th H3 ES1 ? > > > > Sorry for my confusable mail. > > All FCP on H3 ES1 is using above, > > but, M3 or E3 will use different clock. > > > > Is this more clear ? > > Does it mean that every FCP instance uses both the S2D2 and the S2D1 clocks as > functional clocks on H3 ES1 ? - s2d2 (200MHz) is for APB-IF, - s2d1 (400MHz) is for AXI-IF, and internal Is this clear answer ? -- To unsubscribe from this list: send the line "unsubscribe linux-media" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html