Hi Daniel, Daniel Jeong wrote:
Added more comment about Input voltage flash monitor and external temp function. Signed-off-by: Daniel Jeong <gshark.jeong@xxxxxxxxx> --- Documentation/DocBook/media/v4l/controls.xml | 18 ++++++++++++++++++ 1 file changed, 18 insertions(+) diff --git a/Documentation/DocBook/media/v4l/controls.xml b/Documentation/DocBook/media/v4l/controls.xml index a5a3188..145a127 100644 --- a/Documentation/DocBook/media/v4l/controls.xml +++ b/Documentation/DocBook/media/v4l/controls.xml @@ -4370,6 +4370,24 @@ interface and may change in the future.</para> <entry>The flash controller has detected a short or open circuit condition on the indicator LED.</entry> </row> + <row> + <entry><constant>V4L2_FLASH_FAULT_UNDER_VOLTAGE</constant></entry> + <entry>Flash controller voltage to the flash LED + has been below the minimum limit specific to the flash + controller.</entry> + </row> + <row> + <entry><constant>V4L2_FLASH_FAULT_INPUT_VOLTAGE</constant></entry> + <entry>The flash controller has detected adjustment by IVFM + (Input Voltage Flash Monitor) block. + If during the flash current turn-on, the input voltage falls + below the threshold input voltage, IVFM adjust level</entry>
Could you add an explanation what does this fault actually mean to the user? "IVFM" at least doesn't say anything to me...
+ </row> + <row> + <entry><constant>V4L2_FLASH_FAULT_LED_OVER_TEMPERATURE</constant></entry> + <entry>The flash controller has detected that TEMP input has + crossed threshold by external temperature sensor.</entry>
How about this instead? "The temperature of the LED has exceeded its allowed upper limit." -- Kind regards, Sakari Ailus sakari.ailus@xxxxxx -- To unsubscribe from this list: send the line "unsubscribe linux-media" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html