Hi Christophe, Thank you for the patch. On Mon, Apr 17, 2023 at 12:14:42AM +0200, Christophe JAILLET wrote: > If imx296_read() returns an error, its returned value is a negative value. > But because of the "& IMX296_TMDOUT_MASK" (i.e. 0x3ff), 'tmdout' can't be > negative. > > So the error handling does not work as expected and a wrong value is used > to compute the temperature. > > Apply the IMX296_TMDOUT_MASK mask after checking for errors to fix it. > > Fixes: cb33db2b6ccf ("media: i2c: IMX296 camera sensor driver") > Signed-off-by: Christophe JAILLET <christophe.jaillet@xxxxxxxxxx> Dan Carpenter has submitted the same fix in https://lore.kernel.org/linux-media/Y%2FYf19AE78jn5YW7@kili/. Sakari, could you please pick it up ? > --- > drivers/media/i2c/imx296.c | 4 +++- > 1 file changed, 3 insertions(+), 1 deletion(-) > > diff --git a/drivers/media/i2c/imx296.c b/drivers/media/i2c/imx296.c > index 4f22c0515ef8..c3d6d52fc772 100644 > --- a/drivers/media/i2c/imx296.c > +++ b/drivers/media/i2c/imx296.c > @@ -922,10 +922,12 @@ static int imx296_read_temperature(struct imx296 *sensor, int *temp) > if (ret < 0) > return ret; > > - tmdout = imx296_read(sensor, IMX296_TMDOUT) & IMX296_TMDOUT_MASK; > + tmdout = imx296_read(sensor, IMX296_TMDOUT); > if (tmdout < 0) > return tmdout; > > + tmdout &= IMX296_TMDOUT_MASK; > + > /* T(°C) = 246.312 - 0.304 * TMDOUT */; > *temp = 246312 - 304 * tmdout; > -- Regards, Laurent Pinchart