If imx296_read() returns an error, its returned value is a negative value. But because of the "& IMX296_TMDOUT_MASK" (i.e. 0x3ff), 'tmdout' can't be negative. So the error handling does not work as expected and a wrong value is used to compute the temperature. Apply the IMX296_TMDOUT_MASK mask after checking for errors to fix it. Fixes: cb33db2b6ccf ("media: i2c: IMX296 camera sensor driver") Signed-off-by: Christophe JAILLET <christophe.jaillet@xxxxxxxxxx> --- drivers/media/i2c/imx296.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/drivers/media/i2c/imx296.c b/drivers/media/i2c/imx296.c index 4f22c0515ef8..c3d6d52fc772 100644 --- a/drivers/media/i2c/imx296.c +++ b/drivers/media/i2c/imx296.c @@ -922,10 +922,12 @@ static int imx296_read_temperature(struct imx296 *sensor, int *temp) if (ret < 0) return ret; - tmdout = imx296_read(sensor, IMX296_TMDOUT) & IMX296_TMDOUT_MASK; + tmdout = imx296_read(sensor, IMX296_TMDOUT); if (tmdout < 0) return tmdout; + tmdout &= IMX296_TMDOUT_MASK; + /* T(°C) = 246.312 - 0.304 * TMDOUT */; *temp = 246312 - 304 * tmdout; -- 2.34.1