On Wed, Jul 10, 2024 at 12:06:51PM +0200, Lukasz Majewski wrote: > This patch provides support for enabling blinking of LEDs when RX or TX > errors are detected. > > Approach taken in this patch is similar to one for TX or RX data > transmission indication (i.e. TRIGGER_NETDEV_TX/RX attribute). > > One can inspect transmission errors with: > ip -s link show eth0 > > Example LED configuration: > cd /sys/devices/platform/amba_pl@0/a001a000.leds/leds/ > echo netdev > mode:blue/trigger && \ > echo eth0 > mode:blue/device_name && \ > echo 1 > mode:blue/tx_err > > Signed-off-by: Lukasz Majewski <lukma@xxxxxxx> Reviewed-by: Andrew Lunn <andrew@xxxxxxx> Andrew