[PATCH v3 5/5] leds: lm3692x: Use flags from LM3692X_BRT_CTRL

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Use LM3692X_RAMP_EN instead of LM3692X_PWM_HYSTER_4LSB
since the later is a flag for the PWM register. The
actual register value remains unchanged.

Signed-off-by: Guido Günther <agx@xxxxxxxxxxx>
Reviewed-by: Dan Murphy <dmurphy@xxxxxx>
Acked-by: Pavel Machek <pavel@xxxxxx>
---
 drivers/leds/leds-lm3692x.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/leds/leds-lm3692x.c b/drivers/leds/leds-lm3692x.c
index a57b1571e359..8b408102e138 100644
--- a/drivers/leds/leds-lm3692x.c
+++ b/drivers/leds/leds-lm3692x.c
@@ -269,7 +269,7 @@ static int lm3692x_init(struct lm3692x_led *led)
 		goto out;
 
 	ret = regmap_write(led->regmap, LM3692X_BRT_CTRL,
-			LM3692X_BL_ADJ_POL | LM3692X_PWM_HYSTER_4LSB);
+			LM3692X_BL_ADJ_POL | LM3692X_RAMP_EN);
 	if (ret)
 		goto out;
 
-- 
2.23.0.rc1